資源描述:
《集中供熱入網(wǎng)對外實施技術(shù)指南(濟(jì)南熱電有限公司)》由會員上傳分享,免費在線閱讀,更多相關(guān)內(nèi)容在行業(yè)資料-天天文庫。
1、集中供熱入網(wǎng)對外實施技術(shù)指南濟(jì)南熱電有限公司二〇一一年五月9目錄一、政府文件的執(zhí)行··············································2二、樓內(nèi)供用熱設(shè)施建設(shè)要點······································3三、供熱管網(wǎng)建設(shè)要點············································4四、換熱站建設(shè)要點··············································4五、遠(yuǎn)傳抄表管理系統(tǒng)技術(shù)規(guī)范及技術(shù)說明············
2、··············51.工作內(nèi)容·····················································52.標(biāo)準(zhǔn)·························································63.設(shè)計要求·····················································64.通訊方式·····················································85.現(xiàn)場采集單元要求···············
3、······························8六、市政建設(shè)要求·················································81.主要技術(shù)標(biāo)準(zhǔn)··················································82.探測精度······················································893.地下管線測量精度··············································94.管網(wǎng)普查要求·······
4、···········································9一、政府文件的執(zhí)行1.濟(jì)南市人民政府文件《濟(jì)南市人民政府關(guān)于印發(fā)濟(jì)南市城市建設(shè)綜合配套費征收管理辦法的通知》(濟(jì)政發(fā)[2003]3號文),熱源管網(wǎng)建設(shè)費按所建設(shè)項目的供熱建設(shè)面積計收,每平方米78元。2.根據(jù)《濟(jì)南市城市集中供熱管理條例實施細(xì)則》第十二條:“在城市供熱主管網(wǎng)到達(dá)的地區(qū),必須實行集中供熱,需要增加供熱管網(wǎng)的用戶,應(yīng)向供熱單位提出申請,由供熱單位按規(guī)定程序報批并負(fù)責(zé)組織施工”的規(guī)定,新入網(wǎng)用戶紅線內(nèi)的供用熱設(shè)施(外網(wǎng)及換熱站)統(tǒng)一由我公司負(fù)責(zé)施工,樓內(nèi)采暖設(shè)施
5、盡量由我公司負(fù)責(zé)施工。93.根據(jù)魯建發(fā)〔2010〕5號文《關(guān)于進(jìn)一步加強(qiáng)供熱計量管理加快推進(jìn)供熱計量改革的通知》規(guī)定:“新建建筑和納入節(jié)能改造的既有建筑的供熱計量和溫控裝置的購置及安裝費用,由開發(fā)建設(shè)單位在辦理施工許可手續(xù)前一并交給供熱企業(yè),由供熱企業(yè)依據(jù)本地供熱計量規(guī)劃和供熱計量實施方案的要求,統(tǒng)一采購并組織安裝。開發(fā)建設(shè)單位不得擅自采購安裝?!钡囊?,凡屬我公司供熱范圍內(nèi)參加集中供熱的熱用戶,分戶熱計量裝置及溫控裝置統(tǒng)一由我公司組織實施。4.根據(jù)魯建發(fā)〔2010〕5號文《關(guān)于進(jìn)一步加強(qiáng)供熱計量管理加快推進(jìn)供熱計量改革的通知》“無論新建建筑,還是已完成節(jié)能
6、改造的既有建筑,必須安裝熱計量表和溫控裝置,必須達(dá)到供熱計量要求。對不達(dá)標(biāo)的,一律不予竣工驗收備案,不予并網(wǎng)供熱”之規(guī)定,因此,戶外應(yīng)加裝熱量表,室內(nèi)散熱器加設(shè)恒溫閥。熱量表遠(yuǎn)傳數(shù)據(jù)抄表系統(tǒng)必須同步建設(shè)。5.根據(jù)JJG225-2001《中華人民共和國國家計量檢定規(guī)程》“熱能表首次使用須進(jìn)行強(qiáng)制性檢定,熱能表的檢定周期一般不得超過3年”規(guī)定,熱量表安裝前須進(jìn)行首次使用檢定工作。6.根據(jù)魯建發(fā)[2009]11號關(guān)于印發(fā)《山東省房地產(chǎn)開發(fā)項目竣工綜合驗收備案辦法》的通知“第二條凡在山東省城市規(guī)劃區(qū)范圍內(nèi),從事房地產(chǎn)開發(fā)經(jīng)營的,應(yīng)執(zhí)行房地產(chǎn)開發(fā)項目竣工綜合驗收備案制
7、度。第四條房地產(chǎn)開發(fā)項目竣工后,開發(fā)企業(yè)應(yīng)組織相關(guān)部門和單位進(jìn)行綜合驗收,對符合條件,相關(guān)部門和單位應(yīng)出具相應(yīng)的竣工驗收合格證明。分期開發(fā)的項目,可以分期綜合驗收。第六條開發(fā)項目經(jīng)綜合驗收合格后,方可交付使用;綜合驗收不合格的,不得交付使用?!敝?guī)定,開發(fā)企業(yè)應(yīng)在開發(fā)項目竣工驗收合格后十五日內(nèi),按《山東省房地產(chǎn)開發(fā)項目竣工綜合驗收備案辦法》有關(guān)規(guī)定到供熱主管部門辦理相關(guān)備案手續(xù),否則,不得交付使用。7.根據(jù)魯建燃字[2011]11號《關(guān)于進(jìn)一步強(qiáng)化措施深入扎實做好供熱計量改革工作的通知》第四條“各級供熱主管部門是供熱計量改革的責(zé)任主體,要切實履行政府供熱計量
8、管理職能,要從供熱工程項目的規(guī)劃、設(shè)計、施工、竣工驗