某冶金機(jī)械廠總降壓變電所與高壓供電系統(tǒng)設(shè)計(jì)

某冶金機(jī)械廠總降壓變電所與高壓供電系統(tǒng)設(shè)計(jì)

ID:21005316

大小:7.07 MB

頁(yè)數(shù):53頁(yè)

時(shí)間:2018-10-18

某冶金機(jī)械廠總降壓變電所與高壓供電系統(tǒng)設(shè)計(jì)_第1頁(yè)
某冶金機(jī)械廠總降壓變電所與高壓供電系統(tǒng)設(shè)計(jì)_第2頁(yè)
某冶金機(jī)械廠總降壓變電所與高壓供電系統(tǒng)設(shè)計(jì)_第3頁(yè)
某冶金機(jī)械廠總降壓變電所與高壓供電系統(tǒng)設(shè)計(jì)_第4頁(yè)
某冶金機(jī)械廠總降壓變電所與高壓供電系統(tǒng)設(shè)計(jì)_第5頁(yè)
資源描述:

《某冶金機(jī)械廠總降壓變電所與高壓供電系統(tǒng)設(shè)計(jì)》由會(huì)員上傳分享,免費(fèi)在線閱讀,更多相關(guān)內(nèi)容在工程資料-天天文庫(kù)。

1、專業(yè)文檔某冶金機(jī)械廠總降壓變電所及配電系統(tǒng)設(shè)計(jì)摘要隨著我國(guó)國(guó)民經(jīng)濟(jì)的飛速發(fā)展,工業(yè)對(duì)電力的需求也越來越迫切。隨著中國(guó)工業(yè)規(guī)模的不斷擴(kuò)大,對(duì)電力供應(yīng)的安全性、可靠性提出了更高的要求,因此電力系統(tǒng)與用戶直接關(guān)聯(lián)的供電系統(tǒng)尤為重要。作為供電系統(tǒng)的主要組成部分,電氣設(shè)備的質(zhì)量及其性能的先進(jìn)性是決定供電系統(tǒng)安全可靠運(yùn)行的前提條件之一。本設(shè)計(jì)根據(jù)該冶金機(jī)械廠的相關(guān)資料和實(shí)際情況,對(duì)該廠的總降壓變電所和高壓供電系統(tǒng)進(jìn)行設(shè)計(jì)。本設(shè)計(jì)首先根據(jù)工廠提供的資料對(duì)工廠的負(fù)荷情況進(jìn)行了計(jì)算,根據(jù)負(fù)荷情況對(duì)變壓器的容量和臺(tái)數(shù)進(jìn)行了選擇。該廠電源由某變電所以35kV雙回路架空線引出,本設(shè)計(jì)選擇在該廠設(shè)立總

2、降壓變電所先將電壓降為廠區(qū)供電電壓10kV,在由各車間變電所降為負(fù)荷所需電壓。為保證供電系統(tǒng)的可靠性,總降壓變電所采用單母線分段式接線方式,廠區(qū)供電系統(tǒng)采用放射式接線方式。通過計(jì)算,本設(shè)計(jì)對(duì)各變電所的主要電氣設(shè)備、電纜和母線進(jìn)行了選擇和校驗(yàn),對(duì)一次側(cè)主要設(shè)備進(jìn)行了繼電保護(hù)整定,對(duì)避雷和接地裝置進(jìn)行了選擇。關(guān)鍵詞:變電所;供電系統(tǒng);電氣設(shè)備WORD資料可編輯專業(yè)文檔WORD資料可編輯專業(yè)文檔TitleADesignofHighVoltagePowerSupplySystemandSubstationforOneMetallurgicalMachineryPlantAbstrac

3、tWiththerapiddevelopmentofChinesenationaleconomy,demandofindustrialelectricityisalsomoreurgent.WiththeconstantexpansionofChineseindustry,thesecurityofelectricitysupply,higherrequirementsforreliability,powersystemandtheuserthereforedirectlyrelatedtothepowersupplysystemisparticularlyimportant

4、.Asamajorcomponentofpowersupplysystem,electricalequipmentqualityandperformanceofadvancedpowersupplysystemistodeterminethesafeandreliableoperationofoneoftheprerequisites.ThedesignofMetallurgicalMachineryPlantundertherelevantinformationandcircumstances,theplant'sgeneralstepdownsubstationandhi

5、ghvoltagepowersupplysystemdesign.First,thedesignofinformationprovidedundertheplantloadfactoryconditionswerecalculated,accordingtoloadsituationonthetransformercapacityandnumberswereselected.Theplantispoweredbyasubstationto35kVdoublecircuitoverheadlineextraction,theestablishmentofthedesigncho

6、icesintheplantreducedthetotalvoltagestep-downsubstationplantfirstsupplyvoltage10kV,theloadisreducedbytheplantsubstationrequiredvoltage.Toensurethereliabilityofpowersupplysystem,thetotalstep-downsubstationsinglebussegmentalwiring,thefactorypowersupplysystemwithradialterminals.Bycalculating,t

7、hedesignofthemainelectricalsubstationequipment,cablesandbusselectionandvalidationcarriedoutonthelightningprotectionandgroundingdevicesofchoice.Keywords:Substation;PowerSystem;ElectricalEquipmentWORD資料可編輯專業(yè)文檔目次1緒論11.1工廠供電的意義及要求11.2工廠供電設(shè)計(jì)的一般原則21.3設(shè)計(jì)的具體內(nèi)容21

當(dāng)前文檔最多預(yù)覽五頁(yè),下載文檔查看全文

此文檔下載收益歸作者所有

當(dāng)前文檔最多預(yù)覽五頁(yè),下載文檔查看全文
溫馨提示:
1. 部分包含數(shù)學(xué)公式或PPT動(dòng)畫的文件,查看預(yù)覽時(shí)可能會(huì)顯示錯(cuò)亂或異常,文件下載后無(wú)此問題,請(qǐng)放心下載。
2. 本文檔由用戶上傳,版權(quán)歸屬用戶,天天文庫(kù)負(fù)責(zé)整理代發(fā)布。如果您對(duì)本文檔版權(quán)有爭(zhēng)議請(qǐng)及時(shí)聯(lián)系客服。
3. 下載前請(qǐng)仔細(xì)閱讀文檔內(nèi)容,確認(rèn)文檔內(nèi)容符合您的需求后進(jìn)行下載,若出現(xiàn)內(nèi)容與標(biāo)題不符可向本站投訴處理。
4. 下載文檔時(shí)可能由于網(wǎng)絡(luò)波動(dòng)等原因無(wú)法下載或下載錯(cuò)誤,付費(fèi)完成后未能成功下載的用戶請(qǐng)聯(lián)系客服處理。