資源描述:
《高頻振搗對機(jī)場道面引氣混凝土抗凍性能的影響研究》由會員上傳分享,免費(fèi)在線閱讀,更多相關(guān)內(nèi)容在工程資料-天天文庫。
1、學(xué)兔兔www.xuetutu.com2013年第7期(總第285期)混凝土實(shí)用技術(shù)Number7in2013(TotalNo.285)ConcretePRACTICALTECHN0LOGYdoi:10.3969/j.issn.1002-3550.2013.07.045高頻振搗對機(jī)場道面引氣混凝土抗凍性能的影響研究敦曉,張恒’,程愛東’,黃奇,何玉成,黃命輝。,付亞偉。,梅軍杰(1.定襄縣93406部隊(duì),山西忻州035409;2.空軍工程設(shè)計(jì)研究局,北京100068;3.空軍第六空防工程處,湖南衡陽421000;4.肥城市94253部隊(duì),山東肥城271600)
2、摘要:研究了高頻振搗對不同配合比機(jī)場道面引氣混凝土氣泡參數(shù)的影響,并采用抗凍試驗(yàn)對試驗(yàn)數(shù)據(jù)進(jìn)行了驗(yàn)證。結(jié)果表明:適時(shí)的高頻振搗有利于改善引氣混凝土氣泡結(jié)構(gòu),但過度的高頻振搗對引氣劑混凝土氣泡結(jié)構(gòu)會產(chǎn)生不利影響。只要高頻振搗的時(shí)間控制在合理范圍內(nèi),會提高混凝土抗凍性而不會對其性能產(chǎn)生不利影響。試驗(yàn)結(jié)果對工程施工人員正確認(rèn)識高頻振搗對引氣混凝土性能的影響有一定的指導(dǎo)意義。關(guān)鍵詞:高頻振搗;引氣;含氣量;氣泡孔徑;氣泡間隔系數(shù);抗凍性能中圖分類號:TU528.01文獻(xiàn)標(biāo)志碼:A文章編號:1002—3550(2013)07—0159—04Researchofhigh
3、—frequencyvibrationonfrostresistanceofairportpavementair-entrainedconcreteDUNXiao,ZHANGHeng,CHENGAidongI,HUANGOf,HEYucheng2,HUANGMinghui3,FUYawei3,MEIJunjie(1.93406TroopsinDingxiang,Xinzhou035409,China;2.Aft'forceEngineeringDesignandResearchInstitute,Beijing100068,China;3.No.6AirDe
4、fenceEngineeringUnitofAirForce,Hengyang421000,China;4.94253TroopsinFeicheng,F(xiàn)eicheng271600,China)Abstract:Itwasmadeofhowhi曲一frequencyvibrationaffectsthebubbleparametersofairportpavementair—entrainedconcremwithdifferentproportions,andthenthetestdatawerecertifiedthroughantifreezetest
5、s.Theresultsshowedthattimelyhigh-frequencyvibrationwentalongwaytowardstheimprovementinthebubblestructureofair—entrainedconcrete,butexcessivehigh—frequencyvibrationwouldproduceanadverseeffectonthebubblestruc~'eofair-entrainedconcrete.Aslongasthetimeofhigh—frequencyvibrationwascontro
6、lledwithinareasonablelimit,suchvibrationwouldimprovetheresistanceofconcretetofrostwithoutadverselyaffectingitsperformance.Theresultsofthetestscouldprovidesomeguidanceforthoseinvolvedinconstructionastothecorrectunderstandingofhowhi曲一frequencyvibrationaffectstheperformanceofair·entra
7、inedconcrete.Keywords:hi曲一frequencyvibration;air-entrained;aircontent;bubbleaperture;bubblespacingfactor;frostresistance般會使新拌引氣混凝土產(chǎn)生較大的含氣量損失,這是否會0引言影響到硬化混凝土的抗凍性,會產(chǎn)生怎樣的影響,逐漸成影響混凝土抗凍性的因素很多,其中引氣作用最為重工程界亟待解決的疑慮[3]。本研究通過在試驗(yàn)室內(nèi)模擬現(xiàn)要f1],由引氣劑引人的氣泡能在很大程度上削弱自然環(huán)境場高頻振搗,測定新拌和硬化混凝土的氣泡特征參數(shù)隨對混凝土的凍融破
8、壞作用。在一定含氣量下,混凝土的抗凍高頻振搗時(shí)間增加