資源描述:
《CMD鈔箱無法識別或鈔箱數(shù)據(jù)丟失情況處理》由會員上傳分享,免費(fèi)在線閱讀,更多相關(guān)內(nèi)容在行業(yè)資料-天天文庫。
1、CMDV4現(xiàn)場服務(wù)通告鈔箱無法識別或鈔箱數(shù)據(jù)丟失情況處理Version:01.05Date:27/06/2005DocumentNumberBS2005-1WincorNixdorfChinaCustomerServicesWincorNixdorfRetail&BankingSystems(Shanghai)Co.,Ltd.DocumentDetailsDocumentRevisionHistoryVersionDateRevisedbyCommentV0.1June27,2005HuangQingCMDV4ContactInformationNamePho
2、neEmailHuangQing13816337157Qing.huang@wincor-nixdorf.comReviewedbyNameTitleEmailYangXiaojunTechnicalmanagerXiaojun.yang@wincor-nixdorf.comCopyrightThisdocumentisprivate&confidential.MaterialscontainedinthisdocumentrepresentproprietaryinformationpertainingtoWincorNixdorfanditsproject
3、implementationapproachandmethodology.AllTrademarksareherebyacknowledged.Allreferencestothirdpartyproducts,partnersandexistingorfutureWincorNixdorfClientsshouldbeconsideredasconfidentialandmaynotbedistributedwithoutWincorNixdorf’swrittenconsent.ServiceWincor-NixdorfChinaPage6of6Winco
4、rNixdorfRetail&BankingSystems(Shanghai)Co.,Ltd.鈔箱數(shù)據(jù)丟失的處理前言:再次強(qiáng)調(diào)此文檔僅用于協(xié)助工程師現(xiàn)場排除故障,工程師不得以任何原因?qū)⒈疚臋n傳與競爭對手,或者將本文描述的設(shè)備故障傳閱與銀行。問題描述:鈔箱數(shù)據(jù)丟失或者鈔箱無法被識別,無法混用。原因:鈔箱控制板壞,或者鈔箱控制板上使用的電容不匹配。解決方案:1更換鈔箱控制板;2更換鈔箱控制板上的電容;如下圖所示步驟:1.請小心打開圖中1-8的固定搭扣(推薦),打開鈔箱右側(cè)的外板,拆下外板內(nèi)的鈔箱控制板。7831462ServiceWincor-NixdorfChi
5、naPage6of6WincorNixdorfRetail&BankingSystems(Shanghai)Co.,Ltd.5ServiceWincor-NixdorfChinaPage6of6WincorNixdorfRetail&BankingSystems(Shanghai)Co.,Ltd.2.取出控制板,拆下圖中所示電纜線。錯誤的1nf電容3.更換整個控制板,或者將控制板上的1nf電容更換為22pf電容。ServiceWincor-NixdorfChinaPage6of6WincorNixdorfRetail&BankingSystems(Shangh
6、ai)Co.,Ltd.正確的22pf電容4.恢復(fù)。注意,在外板安裝回去的同時,注意請確認(rèn)圖中的灰色連桿的2端的綠色和灰色的螺釘已經(jīng)固定。ServiceWincor-NixdorfChinaPage6of6